Carling offers a wide array of hydraulic magnetic circuit breakers from 02 to 700 amps with ul csa vde tuv ul489 ul489a ul1500 certifications.
Hydraulic magnetic circuit breaker operation.
On the other hand in hydraulic magnetic type you can use the 800a frame breaker.
For example in thermal type when the load is 800a you must select the 1000a frame breaker.
Included among these offerings are the h series breaker and the g series din rail mount breaker both of which meet iec spacing requirements and the compact cx series breaker designed to meet.
Magnetic hydraulic circuit breakers use the principle of magnetic effects of current to operate.
Thermal circuit breakers can be used as the main switch and be reset after tripping but they are heat sensing devices that are affected by changes in ambient temperature.
Time delays a wide range of time delays is avai lable for optimal application compatibility.
Hydraulic magnetic circuit breakers operate on the magnetic force produced by the load current flowing through a series connected solenoid coil which is wound around a hermetically sealed tube containing an iron core a spring and a dampening fluid.
An expanding contact for overload protection and an induction coil for fault protection.
800a hydraulic magnetic type corresponds to 1000a thermal type.
It means that hydraulic magnetic type is sufficient to use 80 of the rated current of thermal type.
Hydraulic magnetic circuit breaker operation.
Hydraulic magnetic circuit breakers on the other hand accomplish both types of.
Although similar in operation to the standard magnetic circuit breaker the magnetic hydraulic circuit breaker differs as the latter has a hydraulic time delay mechanism.
Hydraulic magnetic operation is precise and not affected by changes in ambient temperatures.
These protectors are.
Hydraulic magnetic circuit protectors have hydraulic magnetic current sensing mechanisms which operate only to current changes in the protected circuit.
Operation in the case of a short circuit is quite different.
Here the magnetic flux produced by the coil is enough to attract the armature to the pole face and trip the breaker though the core has.
All mors smitt circuit breakers can be equip ped with a terminal of your choice to save installation time.
Normal overload operation at currents below the circuit breaker rating the magnetic flux in the solenoid is insufficient to.